SubmittalPack

CSI MasterFormat Division 08 Template · Openings

CSI Division 08 Openings Submittal Packet Template

Free CSI Division 08 Openings submittal packet template covering Hollow Metal Doors (08 11 13), Flush Wood Doors (08 14 16), Door Hardware (08 71 00), and Glazing (08 80 00). Compile white-label PDFs in your browser.

CSI Sections Covered
4 Sections
Seeded Cut Sheets
6 Verified Items
PDF Output Branding
100% White-Label

Interactive Pre-Submission Audit

Architect Pre-Submission Checklist — Division 08 (Openings)

Verify every coordination point before exporting your submittal PDF to avoid costly Revise & Resubmit delays.

0 / 7 Verified (0%)

Pre-Loaded Manufacturer Literature

Division 08 CSI Cut-Sheet Specification Schedule

Load All 6 Items in Compiler
CSI SectionManufacturer & ProductStandards & ListingsKey Engineering SpecsAction
08 11 13
Hollow Metal Doors and Frames
L-Series Hollow Metal Door & F-Series Welded Frame
Allegion / Steelcraft · L18-3070 / F16-575

Full-flush heavy-duty 18-gauge cold-rolled steel door with patented interlocked vertical edge seams and 16-gauge welded masonry/drywall frame for high-traffic healthcare corridors.

ANSI/SDI A250.8 Level 2 Heavy DutyUL 10C 3-Hour Positive Pressure Fire RatedNFPA 80 & NFPA 252 CompliantASTM A1008 Cold-Rolled Steel
  • Face Sheets: 18-gauge (0.042 in / 1.0 mm) A60 galvannealed steel
  • Door Thickness: 1-3/4 in (44.5 mm) full flush beveled lock & hinge edges
  • Core Construction: Resin-impregnated kraft honeycomb bonded under heat/pressure
Load Item
08 14 16
Flush Wood Doors
Heritage Architectural 5-Ply Flush Wood Door
VT Industries · 5501-SCLC5-90M

Architectural 5-ply hot-press bonded flush wood door with structural composite lumber core (SCLC-5) and AWI Premium Grade plain-sliced white oak face veneer.

WDMA I.S.1A Extra Heavy DutyAWI Quality Standards Premium GradeUL 10C 90-Minute Positive PressureFSC Mix Credit / CARB Phase 2 Compliant
  • Construction: 5-ply hot-press bonded with Type I water-resistant adhesive
  • Core Type: SCLC-5 Structural Composite Lumber Core (high screw holding)
  • Face Veneer: Plain-sliced White Oak, book-matched & running-matched
Load Item
08 71 00
Door Hardware
L9000 Series Heavy-Duty Mortise Lockset
Allegion / Schlage · L9050P-06A-626

Commercial Grade 1 mortise lockset engineered for hospitals, universities, and civic corridors with universal field-reversible case and anti-sag dual compression springs.

ANSI/BHMA A156.13 Series 1000 Grade 1UL 10C 3-Hour Fire Door ListedADA / ICC A117.1 Ergonomic Lever ReturnFCC / California Title 24 Compliant
  • Lock Function: L9050 Office / Entry (deadlocking latchbolt, toggle stop)
  • Case Material: Heavy-gauge cold-rolled steel, zinc dichromate plated
  • Latchbolt: 3/4 in throw stainless steel antifriction two-piece latch
Load Item
08 71 00
Door Hardware
4040XP Heavy-Duty Surface Door Closer
Allegion / LCN · 4040XP-RW/PA-689

Extra-heavy-duty cast-iron surface closer built for institutional doors with 44% increased bearing load capacity, forged steel main arm, and all-weather hydraulic fluid.

ANSI/BHMA A156.4 Grade 1 (>10M Cycles)UL / cUL Listed for Self-Closing Fire DoorsADA <= 5 lbf Interior Opening ForceISO 9001 Certified Manufacturing
  • Cylinder Body: Cast iron alloy with 1-1/2 in diameter heat-treated piston
  • Spring Power: Field-adjustable spring sizes 1 through 6 (non-handed)
  • Mounting: Regular arm, top jamb, or parallel arm (PA shoe included)
Load Item
08 71 00
Door Hardware
99 Series Heavy-Duty Rim Exit Device
Allegion / Von Duprin · 99L-NL-3FT-26D

Heavy-duty grooved-case rim panic and fire exit device engineered for high-abuse stairwell egress and corridor doors, paired with 996L breakaway lever trim.

ANSI/BHMA A156.3 Grade 1 Exit DeviceUL 305 Panic Hardware / UL 10C 3-Hour FireNFPA 101 Life Safety Code CompliantHurricane & Windstorm Tested (FBC)
  • Device Type: Single-door or mullion-pair rim exit device, 36 in nominal
  • Mechanism Case: Extruded aluminum grooved case with deadlocking latchbolt
  • Latchbolt: 3/4 in throw stainless steel Pullman deadlocking latch
Load Item
08 80 00
Glazing
Solarban 70 Low-E Triple-Silver Insulating Glass Unit
Vitro Architectural Glass · SB70-1IN-ARGON-CLR

High-performance 1-inch clear triple-silver magnetron sputtered Low-E insulating glass unit delivering balanced daylight transmittance and solar heat gain control.

ASTM C1036 Architectural Flat GlassASTM C1048 Heat-Treated Safety GlazingASTM E2190 IGU Seal Durability (IGCC)NFRC 100 / 200 Thermal Certified
  • IGU Makeup: 6mm Solarban 70 (Surface #2) + 1/2 in 90% Argon + 6mm Clear
  • Overall Thickness: 1.00 in (25.4 mm) dual-sealed silicone/PIB edge seal
  • Visible Light (VLT): 64% visible light transmittance, neutral clear aesthetics
Load Item

Field Review Intelligence

Top 4 Division 08 “Revise & Resubmit” Traps

Common review comments that stall procurement approvals — and how to eliminate them before submitting to the GC and Architect.

Trap #108 71 00

Mechanical Dogging Submitted on Fire-Rated Exit Devices

Why it gets rejected: Submitting standard panic hardware (e.g., 99L) instead of UL 10C fire exit hardware (99-F) without mechanical dogging on rated stairwell doors.

How to prevent it: Call out 99-F fire exit hardware explicitly on stairwell and corridor fire-barrier openings and highlight UL 10C 3-hour compliance.

Trap #208 71 00

Hardware Finish & Backset Mismatches Between Cut Sheets and Door Schedule

Why it gets rejected: Mixing BHMA 626 satin chrome levers with 689 sprayed aluminum closers without noting finish coordination, or overlooking 5-in backset clearance.

How to prevent it: Verify finish codes on every hardware cut sheet and attach a cross-referenced hardware group summary.

Trap #308 11 13

Unmarked Multi-Page Catalogs Without Model Highlighting

Why it gets rejected: Bundling 40-page generic manufacturer catalogs without identifying the exact gauge, core, or model series submitted.

How to prevent it: Submit targeted 1-to-2 page product data sheets with exact model numbers (e.g., L18-3070 / F16-575) indexed in the CSI Table of Contents.

Trap #408 80 00

Missing Glazing Edge-Deletion & Safety Temper Compliance

Why it gets rejected: Omitting Low-E surface coating location (Surface #2 vs #3) or ASTM C1048 tempering documentation for hazardous door/sidelite locations.

How to prevent it: State exact IGU makeup (outer lite, coating surface, argon cavity, inner lite) and CPSC 16 CFR 1201 Cat II compliance on the cut sheet.

Submittal Reference FAQ

Division 08 Submittal Frequently Asked Questions

Which CSI MasterFormat sections belong in a commercial Division 08 submittal packet?

A typical commercial Division 08 Openings package includes 08 11 13 (Hollow Metal Doors and Frames), 08 14 16 (Flush Wood Doors), 08 71 00 (Door Hardware — locksets, closers, exit devices, hinges, gasketing), and 08 80 00 (Glazing), organized sequentially with CSI section dividers and a cover sheet.

Does SubmittalPack put any vendor watermark on my compiled Division 08 PDF?

No. Compiled PDFs are 100% white-label and display only your subcontractor company name, license subtitle, project routing block, and optional architect review stamp box.

Can I mix my own manufacturer PDF cut sheets with the Division 08 template?

Yes. Open the Division 08 preset in the compiler, drop your own Allegion, VT Industries, ASSA ABLOY, or glazing PDFs into the browser vault, reorder them by CSI section, and compile a single unified PDF.

Why do architects reject Division 08 door and hardware submittals on first review?

The most frequent causes of 'Revise & Resubmit' stamps are fire-rating conflicts (dogged panic devices on fire doors), missing frame jamb depth verification, inconsistent BHMA finish codes, and unindexed raw PDF merges lacking a CSI Table of Contents.

Multi-Trade CSI Library

Explore All CSI Division Submittal Templates

Division 08Current

Openings Submittal Template

6 cut sheets · 4 CSI sections · Pre-submission checklist

Division 23

HVAC Submittal Template

6 cut sheets · 6 CSI sections · Pre-submission checklist

Division 26

Electrical Submittal Template

6 cut sheets · 6 CSI sections · Pre-submission checklist

Zero Account Required · Runs 100% Locally in Browser

Ready to assemble your Division 08 (Openings) submittal packet?

Stamp your own subcontractor letterhead, include an architect review box, drag in custom manufacturer PDFs, and export a clean white-label PDF in seconds.

Compile This Division 08 Packet Free — Zero Watermarks