CSI Division 23 HVAC Submittal Packet Template

Free CSI Division 23 HVAC submittal packet template covering Duct Insulation (23 07 13), Controls Actuators (23 09 23), Roof Exhaust Fans (23 34 23), VAV Boxes (23 36 00), Diffusers (23 37 13), and Packaged RTUs (23 74 13).

CSI Sections Covered
6 Sections
Seeded Cut Sheets
6 Verified Items
PDF Output Branding
100% White-Label

Interactive Pre-Submission Audit

Architect Pre-Submission Checklist — Division 23 (HVAC)

Verify every coordination point before exporting your submittal PDF to avoid costly Revise & Resubmit delays.

0 / 7 Verified (0%)

Pre-Loaded Manufacturer Literature

Division 23 CSI Cut-Sheet Specification Schedule

Load All 6 Items in Compiler
CSI SectionManufacturer & ProductStandards & ListingsKey Engineering SpecsAction
23 36 00
Air Terminal Units
SDV Single-Duct VAV Terminal Unit with 2-Row Hot Water Reheat
Price Industries · SDV-08-RH2-F1

Pressure-independent single-duct variable air volume (VAV) terminal unit featuring multi-point SP300 airflow sensor, low-leakage heavy-gauge casing, and factory-mounted 2-row hydronic reheat coil.

AHRI Standard 880 Certified PerformanceUL 181 Erosion & Mold Growth Resistant LinerNFPA 90A Flame/Smoke 25/50 RatedASHRAE Standard 130 Air Terminal Testing
  • Inlet Size / Airflow: 8 in round inlet · 140 to 900 CFM nominal operating range
  • Casing Construction: 22-gauge galvanized steel, mechanically locked low-leakage seams
  • Damper Assembly: Double-thickness 22-ga steel blade with closed-cell foam seal (<2% leakage)
Load Item
23 34 23
HVAC Power Ventilators
Model GB-141 Belt-Drive Centrifugal Roof Exhaust Fan
Greenheck · GB-141-4-QD-X

Spun-aluminum downblast centrifugal roof exhaust ventilator with non-overloading backward-inclined wheel, vibration-isolated drive frame, and factory NEMA 3R disconnect switch.

AMCA 210 Air Performance CertifiedAMCA 300 Sound Performance CertifiedUL / cUL 705 Power Ventilators ListedMiami-Dade / IBC High-Wind Curb Rated
  • Design Performance: 2,150 CFM @ 0.625 in w.g. static pressure, 1,180 RPM
  • Motor & Electrical: 1/2 HP, 208-230/460V 3-phase 60Hz ODP, NEMA Premium Eff.
  • Sound Rating: 10.8 Sones at 5 ft free-field hemispherical inlet
Load Item
23 74 13
Packaged, Outdoor, Central-Station Air-Handling Units
Precedent 10-Ton Packaged Rooftop Unit (Gas/Electric)
Trane · YSC120H4RHA-10T

Commercial 10-ton standard-efficiency packaged rooftop unit with dual-stage scroll compressors, direct-drive plenum ECM supply fan, low-leakage economizer, and Symbio 700 BACnet controller.

AHRI Standard 340/360 CertifiedASHRAE 90.1 Energy Efficiency CompliantUL 60335-2-40 Listed (A2L R-454B Safety)ANSI Z21.47 Gas-Fired Central Furnace
  • Cooling Capacity: 118,000 Btu/h gross (10 Nominal Tons) · 14.8 IEER / 11.2 EER
  • Heating Section: 205,000 Btu/h input stainless steel tubular heat exchanger (81% AFUE)
  • Refrigerant Circuit: Dual independent R-454B circuits with factory A2L leak mitigation sensor
Load Item
23 37 13
Diffusers, Registers, and Grilles
OMNI Architectural Plaque Ceiling Supply Diffuser
Titus HVAC · OMNI-AA-24x24-10IN

Architectural flush-face steel/aluminum plaque ceiling diffuser engineered for uniform 360-degree radial Coanda airflow in open offices, clinical exam rooms, and VAV zones.

ASHRAE Standard 70 Air Outlet TestingADC 1062:GRD-84 Certified PerformanceASTM B209 Architectural Aluminum FaceISO 5219 Air Distribution Aerodynamic Test
  • Module & Neck Size: 24 in x 24 in lay-in T-bar module with 10 in round inlet neck
  • Design Airflow: 350 CFM nominal · Throw 9-13-18 ft (150-100-50 fpm terminal)
  • Pressure & Sound: 0.085 in w.g. total pressure drop · NC 21 acoustic rating
Load Item
23 07 13
Duct Insulation
SOFTR Duct Wrap FRK Foil-Reinforced Kraft Blanket
Owens Corning · SOFTR-FRK-2IN-R6

Flexible formaldehydefree fiberglass blanket insulation factory-laminated to a vapor-retarding FRK (foil-reinforced kraft) facing for exterior thermal and condensation control on HVAC ductwork.

ASTM C1290 Type III Flexible Fibrous BlanketASTM E84 Flame Spread <= 25 / Smoke <= 50NFPA 90A & NFPA 90B HVAC Duct ComplianceUL GREENGUARD Gold Indoor Air Quality
  • Thickness & Density: 2.2 in nominal (1.65 in installed at 25% max compression), 0.75 pcf
  • Installed R-Value: R-6.0 hr*ft2*F/Btu at 75 F mean temperature (ASTM C518)
  • Vapor Retarder Facing: FRK reinforced aluminum foil/kraft with 2 in stapling/taping flange
Load Item
23 09 23
Direct-Digital Control System for HVAC
LMB24-SR Proportional Non-Spring-Return Damper Actuator
Belimo · LMB24-SR-45INLB

Direct-coupled 24V AC/DC modulating brushless DC damper actuator delivering 45 in-lb torque with 2–10V DC proportional control, feedback output, and electronic overload protection.

UL 60730-1 / UL 60730-2-14 RecognizedCSA C22.2 No. 24 CertifiedNEMA 2 / IP54 Enclosure ProtectionISO 9001 Quality Management Certified
  • Torque Output: 45 in-lb (5 Nm) minimum constant torque across full 95 deg stroke
  • Power Supply: 24 VAC +/-20% 50/60 Hz or 24 VDC +/-10% (1.5W running / 0.4W hold)
  • Control Signal: 2 to 10 VDC modulating input (0–10V / 4–20mA with 500-ohm resistor)
Load Item

Field Review Intelligence

Top 4 Division 23 “Revise & Resubmit” Traps

Common review comments that stall procurement approvals — and how to eliminate them before submitting to the GC and Architect.

Trap #123 74 13

MCA / MOP Electrical Mismatch Between RTU Submittal and Panel Schedule

Why it gets rejected: Submitting a packaged rooftop unit whose revised MCA/MOP or SCCR exceeds the circuit breaker and feeder sized by the electrical engineer.

How to prevent it: Highlight Voltage, Phase, MCA, MOP, and SCCR on the equipment cover sheet and flag any variance to Div 26 before submission.

Trap #223 07 13

Nominal vs. Installed Duct Wrap R-Value Confusion

Why it gets rejected: Submitting 1.5-in nominal wrap when energy code requires installed R-6.0 (which requires 2.2-in nominal wrap accounting for 25% corner compression).

How to prevent it: Verify ASTM C1290 installed R-value at 25% compression directly on the insulation data sheet.

Trap #323 36 00

Missing Acoustic NC Ratings on VAV Boxes & Ceiling Diffusers

Why it gets rejected: Submitting airflow capacity tables without AHRI 880 radiated/discharge NC ratings or ASHRAE 70 diffuser sound data for quiet clinical/office zones.

How to prevent it: Include operating-point NC ratings at 1.0 in w.g. delta-P and confirm acoustic liner specs (UL 181 foil-faced vs. closed-cell).

Trap #423 37 13

Wrong Ceiling Grid Border Type on Architectural Diffusers

Why it gets rejected: Ordering standard 15/16 in lay-in diffusers for fine-line 9/16 in slot-grid ceilings or hard gypsum soffits shown on the RCP.

How to prevent it: Cross-reference every diffuser tag against the Architectural Reflected Ceiling Plan before locking border types.

Submittal Reference FAQ

Division 23 Submittal Frequently Asked Questions

What equipment cut sheets are included in this Division 23 HVAC submittal template?

The template includes six core commercial HVAC CSI sections: Duct Insulation (23 07 13), DDC Damper Actuators (23 09 23), Roof Exhaust Fans (23 34 23), Single-Duct VAV Boxes (23 36 00), Architectural Ceiling Diffusers (23 37 13), and 10-Ton Packaged Rooftop Units (23 74 13).

Can mechanical subcontractors upload factory selection software PDFs (Trane TOPSS, Greenheck CAPS, Price AIO)?

Yes. Drag and drop multi-page PDF exports from manufacturer selection tools directly into the browser vault. SubmittalPack copies your original pages byte-for-byte into the compiled white-label packet with continuous Page X of Y numbering.

Do my HVAC equipment selections leave my computer during PDF compilation?

No. In the Web Compiler, all PDF merging, cover sheet generation, and CSI indexing run locally in a Web Worker inside your browser, and uploaded cut sheets persist privately in your browser's IndexedDB.

What causes the most Revise & Resubmit comments from mechanical engineers?

Electrical MCA/MOP mismatches, missing AHRI 880 / AMCA 210 sound and performance ratings, omitting installed R-value compression data on duct wrap, and missing BAS/BACnet integration points.

Multi-Trade CSI Library

Explore All CSI Division Submittal Templates

Division 08

Openings Submittal Template

6 cut sheets · 4 CSI sections · Pre-submission checklist

Division 23Current

HVAC Submittal Template

6 cut sheets · 6 CSI sections · Pre-submission checklist

Division 26

Electrical Submittal Template

6 cut sheets · 6 CSI sections · Pre-submission checklist